CONTACT US
Product Introduction
The Fixed Pollution Source Sulfuric Acid Mist Sampling Gun is specially designed for the collection of sulfuric acid mist from fixed pollution sources. This device uses heating technology to ensure that the temperature of the gun head and body is controlled, preventing moisture condensation and reducing sampling resistance. Solid-state sulfuric acid mist is collected using a standard 3# filter cartridge, while gaseous sulfuric acid mist is collected using two 250ml impact absorption bottles in series. The device also measures the smoke flow rate and temperature during the sampling process. It is widely used in environmental protection, public health, labor, safety supervision, and scientific research.
Product Features
- Full-Heating Design: Both the sampling head and gun body are heated to ensure smooth sampling without condensation, preventing blockage and ensuring an uninterrupted flow of gas through the filter.
- Dual Sulfuric Acid Mist Collection: Solid-state sulfuric acid mist is collected using a standard 3# filter cartridge, while gaseous sulfuric acid mist is captured using two 250ml impact absorption bottles in series, ensuring accurate detection.
- Precise Temperature Control: The gun body temperature is accurately controlled at 110°C ±10°C, providing a stable sampling environment.
- Customizable Length: The standard sampling tube length is 1.5 meters, but it can be customized to suit different sampling scenarios.
- Integrated Measurement Functions: The device can simultaneously measure the smoke flow rate and temperature, ensuring accurate data during the sampling process.
- Variety of Accessories: The device is equipped with various sampling nozzles for different flow rates and features an adjustable height support stand for easy positioning and stabilization during sampling.
Application Fields
- Environmental Monitoring: Widely used in the monitoring of sulfuric acid mist emissions from fixed pollution sources, supporting regulatory standards and environmental monitoring.
- Public Health & Safety: Used in the health, epidemic prevention, and safety supervision sectors for sampling and detecting harmful sulfuric acid mist in the air.
- Scientific Research & Education: Ideal for research institutions and laboratories for the collection and analysis of sulfuric acid mist and exhaust gases.
- Industrial Production: Applied in monitoring sulfuric acid mist emissions from industrial sources, helping enterprises manage pollution and comply with environmental regulations.
Main Parameter | Description |
Sampling Gun Length | 1.5 meters (customizable) |
Pitot Tube Coefficient | 0.84 |
Measurement Hole Diameter Requirement | ≥Ф75mm |
Sampling Nozzle Diameter | 5/6/8/10/12mm |
Temperature Sensor | PT100 |
Heating Temperature | 110±10℃ |