CONTACT US
Product Overview
The Ultrasonic Flow Meter is designed specifically for the distribution and measurement of city gas. It accurately measures the flow of combustible gases using the ultrasonic time-difference method, offering extremely low starting flow rates, high sensitivity, and excellent measurement efficiency. With multi-channel measurement technology, it effectively eliminates the effects of eddy currents and asymmetric flow fields on measurement results, providing necessary redundancy. The product features a measurement accuracy of 1.0 class and is widely applicable for urban pipeline networks. Equipped with intelligent self-diagnostics and remote monitoring capabilities, it offers a comprehensive solution for measurement and management.
Key Features
- Ultrasonic Technology: High accuracy, long service life, and no special maintenance required for long-term operation.
- Multi-Channel Design: Effectively eliminates measurement difficulties caused by unstable flow fields, ensuring precise readings.
- Ultra-Low Starting Flow and Wide Flow Range: Capable of accurate measurement across a wide flow range, fully covering city gas networks.
- Temperature and Pressure Compensation: Equipped with temperature and pressure sensors to ensure precise measurements through compensation.
- No Moving Parts: Reduces mechanical wear, offers low pressure loss, and requires virtually no maintenance.
- Built-in Wireless Data Transmission: Supports remote monitoring, data transfer, and operational diagnostics, facilitating easy management and operation.
- Digital Design: Complete functionality with intuitive display for easy installation and use.
- Durable Design: Constructed with a carbon steel housing and titanium alloy transducers, resistant to contamination and ideal for harsh environments.
- Smart Self-Diagnosis: Monitors the device's status, automatically alarms, and enhances reliability.
- Dual Power System: Supports both external power supply and built-in lithium battery backup, ensuring stable flowmeter operation.
Applications
- City Gas Distribution Measurement: Widely used for flow measurement and monitoring in urban gas networks.
- Natural Gas and Combustible Gas Flow Monitoring: Suitable for accurate flow measurement of various gases, ensuring safe gas supply.
- Industrial Pipeline Flow Measurement: Used for flow monitoring and management in various industrial gas pipelines.
- Environmental Monitoring: Applied in the environmental sector for gas flow detection and control.
Specification Model | DN50 | DN80 | DN100 | DN150 | DN200 | DN250 | DN300 |
Measurement Principle | Ultrasonic Time Difference | Ultrasonic Time Difference | Ultrasonic Time Difference | Ultrasonic Time Difference | Ultrasonic Time Difference | Ultrasonic Time Difference | Ultrasonic Time Difference |
Number of Channels | 2 | 2 | 2 | 3 | 4 | 4 | 4 |
Measurement Range (m³/h) | 2.5–150 | 6–360 | 10–600 | 26–1300 | 40–2000 | 75–3000 | 100–4000 |
Accuracy Level | Level 1.0 | Level 1.0 | Level 1.0 | Level 1.0 | Level 1.0 | Level 1.0 | Level 1.0 |
Cut-off Flow (m³/h) | 15 | 36 | 60 | 130 | 200 | 300 | 400 |
Indication Error | Qmin≤Q<Qt,≤±2.0% | Qt≤Q≤Qmax,≤±1.0% | Qt≤Q≤Qmax,≤±1.0% | Qt≤Q≤Qmax,≤±1.0% | Qt≤Q≤Qmax,≤±1.0% | Qt≤Q≤Qmax,≤±1.0% | Qt≤Q≤Qmax,≤±1.0% |
Fluid Medium | Single-phase gas: natural gas, liquefied petroleum gas, air, etc. | ||||||
Medium Temperature | -20~60℃ | ||||||
Nominal Pressure | ≤1.6MPa | ||||||
Working Pressure | ≤0.6MPa | ||||||
Ambient Temperature | -25~55℃ | ||||||
Power Supply | External power supply 24VDC, built-in lithium battery 3.6V | ||||||
Signal Output | RS-485, 4~20mA, Modbus | ||||||
Wireless Communication | GPRS | ||||||
LCD Display | Accumulated total (standard conditions), instantaneous flow rate under standard conditions, instantaneous flow rate under working conditions, temperature, pressure, battery power, etc. | ||||||
Installation Method | Flange connection installation |